Camille Bauer has long years of experience in the development of instruments which must operate precisely in all external conditions: Our products feature maximum safety for the operating staff and standard aligned functioning under different site and ambient conditions. Highly precise EMC and environmental tests can be conducted at our own test laboratories. In addition, we have the safety and quality of our instruments again and again documented by external accredited test laboratories as well as independent international certification bodies.

Buffer amplifiers (SINEAX TV810)

DC-signal converter (current/voltage)

  • Input: Current bipolar selectable up to 20 mA or voltage
  • Output: Current or voltage
  • Response time: 35 ms
  • Power for 2-...

DC Current Isolator (SINEAX TV804)

  • Input: Current (active or passive)
  • Output: Current (active or passive)
  • Response time: 40 ms
  • Power for 2-wire transducers, 20 V DC
  • 3-way galvanic isola...

Buffer amplifiers (SINEAX TV819)

Isolating amplifier for electrical isolation of DC signals. Processing of unipolar, bipolar and live-zero signals, load boosting and signal conversion option.

  • Electrical isolation betw...

Buffer amplifiers (SINEAX VS50)

DC current / Voltage converter

  • Input: Current 0/4...20 mA or voltage 0/1...5, 0/2...10, 0...15/30 V DC
  • Output: current 0/4...20, 20...4/0 mA or voltage 0/1...5, 0/2...10 V DC...

Buffer amplifiers (SINEAX VS52)

DC current / Voltage converter (with transducer power supply)

  • Input: Current 0/4...20 mA or voltage 0/1...5, 0/2...10 V DC
  • Output: current 0/4...20, 20...4/0 mA or voltage 0/...

Buffer amplifiers (SINEAX TV808-11; SINEAX TV808-115; SINEAX TV808-12)

Isolating amplifier for electrical isolation of DC signals. Processing of unipolar, bipolar and live-zero signals, load boosting and signal conversion option.

  • A variant with one input a...

Temperature transmitters (SINEAX V610)

SINEAX V 610 is a two-wire transmitter. It is designed for measuring temperature in combination with resistance thermometers Pt 100. Thermocouple non-linearities are automatically compensated. The out...

Temperature transmitters (SINEAX V624)

The SINEAX V624 converts measured quantities (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output quantity. Measured quantity and measuring range can be pro...

Temperature transmitters (SINEAX VS30)

Pt100, Ni100 / loop-powered converter

  • Input: Pt100 (- 200...+ 650 °C), Ni100 (- 60...+ 250 °C)
  • Output: Current 4...20 or 20...4 mA
  • Max. consumption 24 mA

Temperature transmitters (SINEAX VS46)

  • Input: Thermocouples types: J, K, E, N, S, R, B, T
  • Output: Current 0/4...20, 20...4/0 mA or voltage 0...5/10, 10...0 and 1...5 V DC, solid state relay (SSR) for thermostat / alarm...

Measurement and Monitoring System (SINEAX A230/A230s)

Multifunctional power monitor with system analysis. Panel mounting, 144 x 144 mm. The A230 is designed for application in high, medium and low voltage systems. Any current and voltage transformers are...

Power Meters (APLUS)

The die is cast.
The APLUS is a new comprehensive unit for the universal measurement, monitoring and power quality analysis in electrical power networks. It complements the product portfol...