Temperature transmitters (SINEAX V624) by Camille Bauer Metrawatt AG

Product inquiry

The SINEAX V624 converts measured quantities (i.e. signal from a thermocouple or a resistance thermometer) into a proportional, analog output quantity. Measured quantity and measuring range can be programmed with a PC: facilitates planning and project work, short lead-times, minimal inventory
  • Integrated cold junction compensation
  • Electrically isolated between input, 2.3 kV output and 3.7 kV auxiliary power / compliant with EN 61 010
  • Power supply: integrated AC-DC power pack with large tolerance range
  • Open-circuit sensor and short-circuit monitoring / defined output performance in the event of disturbance
  • With or without programmable auxiliary power connection
  • The following parameters can also be programmed: data related to the measured quantity (e.g. 2, 3 or 4-wire connection for resistance thermometer, "internal" or "external" cold junction compensation for thermocouple etc.), response characteristics, signal flow direction (measured quantity / output quantity "rising/rising, normal" or "rising/falling, inverse" and details regarding open-circuit sensor monitoring (output quantity as a predetermined fixed value between -10 and 110%) / greatest possible flexibility for the realization of measuring tasks
  • Output calibration, lower and upper value can be trimmed via software
  • Digital measured value information available at the programming interface: facilitates initial start-up, measured values can be displayed at the programming PC
  • Available with "intrinsically safe" explosion protection per [EEx ia] IIC
  • Serial interface
  • P12 housing for top-hat rail mounting

Product inquiry

More Products in the Area of Temperature transmitters

Temperature transmitters (SINEAX V610)

SINEAX V 610 is a two-wire transmitter. It is designed for measuring temperature in combination with resistance thermometers Pt 100. Thermocouple non-linearities are automatically compensated. The out...

Temperature transmitters (SINEAX VS30)

Pt100, Ni100 / loop-powered converter

  • Input: Pt100 (- 200...+ 650 °C), Ni100 (- 60...+ 250 °C)
  • Output: Current 4...20 or 20...4 mA
  • Max. consumption 24 mA

Temperature transmitters (SINEAX VS46)

  • Input: Thermocouples types: J, K, E, N, S, R, B, T