Catalog

KROHNE Messtechnik GmbH

KROHNE Messtechnik GmbH

  • DIN EN ISO 9001

KROHNE Messtechnik GmbH

  • DIN EN ISO 9001

23.10.2020 05:10

SIL 2 option for DK glass devices with NAMUR limit switch

Variable area flowmeters DK46/47/48/800 available with SIL 2 compliance First and only SIL 2 glass tube purgemeters on the market

The variable area (VA) flowmeters DK46/47/48/800 with glass tube are now available with SIL 2 compliance. They are the first and currently the only SIL 2 glass tube purgemeters on the market.

The SIL option is applicable for devices with stainless steel or brass process connections with bistable NAMUR limit switches and junction box. It can be combined with ATEX certifications and also applies to VA flow controllers with individual probability of failures.

Typical applications for the SIL 2 glass tube flowmeters are sample flow monitoring for process analyser systems, gas or liquid supply monitoring for mechanical sealing systems, purging monitoring for measuring systems (e.g. dP flow measurement), or nitrogen inertisation.

More News

• Anniversary kick-off on June 7 with the opening of digital fair "KROHNE Insights" • Creativity as the basis for innovation: during a press conference, Michael Rademacher-Dubbick and Dr Attila Michael Bilgic explained the core values influencing KROHNE history and future
Compact, robust design for parallel installation and tight spaces Best-in-class in terms of temperature range, accuracy, pressure drop and flow range Flow range 0.005..150 l/min, integrated temperature measurement Full colour display and various output options
Economical solution for liquid, (wet) gases, saturated and superheated steam applications Advanced Vortex Frequency Detection (AVFD) technology for stable measurements with demanding process conditions from -40…+240°C / -40…+464°F Flange and sandwich versions with optional integrated nominal diameter reduction Remote option with converter installation up to 50 m / 164 ft from sensor
New loop powered control unit for 4…20mA/HART field devices Second current output, two configurable relays, NAMUR NE 107 status LEDs For basic control applications in various industries
Extension of NE107 device diagnostics to include specific application diagnostics Detection of float blockages, pulsations and incorrect reinstallation after maintenance
OPTITEMP TRA-H6x/-C6x temperature sensors with 3A, FDA and EHEDG approvals. Fast responding sensor tip with reduced heat conducting error for high accuracy at short immersion depths. Modular G½-hygienic connection: steel to steel & steel to PEEK.