Intelligent algorithms increase the application reliability of variable area flowmeters

Extension of NE107 device diagnostics to include specific application diagnostics Detection of float blockages, pulsations and incorrect reinstallation after maintenance

To increase application reliability, additional application diagnostics are now available for the H250 M40 variable area (VA) flowmeter in addition to the electronic device diagnostics. The new functions are implemented via intelligent software algorithms for signal analysis of the magnetic field sensors.

The existing NE107 device diagnosis is thus extended to include VA specific application diagnostics: the device now detects, for example, blockages of the float caused by impurities in the medium or by strong, repeated pressure surges. Pulsations in liquid measurements with positive displacement pumps or compression oscillations in gas measurements are also detected. A message is also reported if the float is installed in the measuring cone upside down or is completely missing after maintenance or cleaning. The signalling severity of the individual diagnostic functions can be configured according to NAMUR NE107 classes: from "for information" to "maintenance required" or "out of specification" to "failure" with activation of the failure current signal.

The new functions not only increase application reliability, but also enable the measuring accuracy and service life of variable area flowmeters to be optimized with appropriate corrective measures. Existing devices can be retrofitted by exchanging modules in the field.

More News

• Anniversary kick-off on June 7 with the opening of digital fair "KROHNE Insights" • Creativity as the basis for innovation: during a press conference, Michael Rademacher-Dubbick and Dr Attila Michael Bilgic explained the core values influencing KROHNE history and future
Compact, robust design for parallel installation and tight spaces Best-in-class in terms of temperature range, accuracy, pressure drop and flow range Flow range 0.005..150 l/min, integrated temperature measurement Full colour display and various output options
Variable area flowmeters DK46/47/48/800 available with SIL 2 compliance First and only SIL 2 glass tube purgemeters on the market
Economical solution for liquid, (wet) gases, saturated and superheated steam applications Advanced Vortex Frequency Detection (AVFD) technology for stable measurements with demanding process conditions from -40…+240°C / -40…+464°F Flange and sandwich versions with optional integrated nominal diameter reduction Remote option with converter installation up to 50 m / 164 ft from sensor
New loop powered control unit for 4…20mA/HART field devices Second current output, two configurable relays, NAMUR NE 107 status LEDs For basic control applications in various industries