Catalog

ifm electronic GmbH

ifm electronic GmbH

  • ISO 9001 : 2015
  • ISO 14001:2015
  • EMAS :2020
  • ISO/IEC 27001

ifm electronic GmbH

  • ISO 9001 : 2015
  • ISO 14001:2015
  • EMAS :2020

Back to the overview

IO-Link-Master by ifm electronic GmbH

Product inquiry  

Powerful IO-Link masters for industrial applications

  • 4-port and 8-port IO-Link masters for field use
  • Daisy-chain power with standardised L-coded M12 connection technology, max. 2 x 16 A
  • Connection of actuators up to 2 A
  • Current measurement and configurable current limitation for each port
  • Master and device configurable via moneo configure software

Robust field bus modules with fail-safe connection
The decentralised IO-Link masters are used as gateways between intelligent IO-Link sensors and the fieldbus. They are the perfect choice, even in the most difficult environments: The materials and production methods are identical to the ifm jumper cables of the tried-and-tested EVC product series. The ecolink technology guarantees reliable, permanently ingressresistant M12 connections of the connection cables.

L-coded cables for high currents
Used to supply higher power levels to the new ifm Performance Line IO-Link masters in demanding applications. The L-coded M12 power connector is becoming more and more established on the market and the perfect solution to supply these modules with power. This allows high currents to be transmitted with low voltage drop. ifm offers connection cables and jumpers that are perfectly adapted to this.

Advantages and customer benefits
16 amps on an M12 connector
The IO-Link master is supplied via the standardised L-coded M12 connector. This connection technology with 5 x 2.5 mm2 can be used to supply sensors and actuators with up to 16 A. The energy can be looped through the master (daisy chain).

Connection of 2 A actuators with high current consumption
Optionally, a digital output mode can be set for pin 2 of a B port. Thus, large solenoid valves and actuators can be switched with up to 2 A.

Energy monitoring
The current for each port can be limited, which can be set in the PLC. Moreover, voltage and current values of each port can be measured. This makes it easy to determine the energy required by an installation and to transfer it to ERP systems for analysis.

Sensor configuration with moneo configure SA
The intuitive software finds all IO-Link masters in the network and creates an overview of the whole plant. Besides, all sensors connected are indicated with the respective parameters. This means that parameter setting of all sensors in the system is possible from one central point.


Product inquiry  

More Products in the Area of IO-Link Components

IO-Link Components

Industry 4.0 made easy - apps instead of expensive programming

Easy as using a smartphone!Individual connection to a PLC by means of reloadable apps

  • Fast and easy i...

IO-Link converter

Digital meets analog: Integrating modern IO-Link sensors in analog mode

  • Converts IO-Link process values into two analog signals 4...20 mA
  • Ideal for IO-Link...