Valve with main gas lock by Borrmann Brenner Berlin GmbH

Product inquiry  

HGS valve with locking nut for installation on gas stoves, stoves or control cabinets

Loosen the handwheel Unscrew the locking nut and push the HGS through the appropriate opening (27 mm).

Then tighten the locking nut and screw the handwheel tight.

The HGS valve is required for all gas burners equipped with a pilot flame.

The gas supply for the main burner is blocked as long as the pilot flame is not burning.

A flame monitor is integrated in this valve which monitors the flame by means of a thermocouple.

If the pilot flame goes out and the thermocouple cools down, the gas supply closes automatically.

No uncontrolled outflow of gas possible.

Gas connection 3x 14x1.5s

Threaded input for the thermocouple M8x1